A solution in a 2.00 cm cell has . Its molar absorptivity is L/(mol cm). Find its concentration in units of mol/L.
Answer and solution
Answer: (accepted range )
.
mol/L, so the answer is 1.0.
FIRST YEAR · CHEMISTRY · CHAPTER 8 OF 8
This chapter explains why molecules absorb light at particular wavelengths, which identifies a compound and measures its concentration. It also covers chromatography and reporting a measurement with its uncertainty, the basis of any lab result an engineer acts on.
Updated 30 Oct 2026
You will be able to say which transition each region of the spectrum drives, and find a concentration from an absorbance. You will read the main bands of an infrared spectrum and the outline of an NMR spectrum. You will compute an value and report repeated readings with their uncertainty.
Chapter 2, Conjugated molecules, bands in solids and coloured complexes
Logarithms to base 10 and powers of ten
A mass on a spring, a harmonic oscillator: it vibrates at angular frequency , faster when the spring is stiffer (larger force constant ) or the mass lighter
Mean, the summation sign , squares and square roots of numbers
A molecule has only certain energy levels, and it absorbs a photon only when the photon's energy equals the gap between two of them. Electronic gaps are large, vibrational gaps smaller, and nuclear spin gaps in a magnetic field tiny. So each kind of transition has its own region of the spectrum.
PHOTON ENERGY AND WAVELENGTH
For one photon and one molecule; multiply by for a mole. J s is Planck's constant, the frequency in Hz, m/s the speed of light, the wavelength in m, /mol. At 500 nm, about 240 kJ/mol.
Region | Wavelength | kJ/mol | Transition |
|---|---|---|---|
UV-visible | 200 to 700 nm | 600 to 170 | Electronic |
Infrared | 2.5 to 25 µm | 48 to 5 | Vibrational |
Radio (NMR) | 0.5 to 1 m | to | Nuclear spin |
Light of intensity enters a solution and leaves. Each thin layer passes the same fraction of the light reaching it, so two layers pass that fraction squared: intensity falls exponentially with path length . The fraction a thin layer removes is proportional to the absorbing molecules in it, so doubling the concentration acts like doubling . Hence , with a constant for each substance and wavelength (base 10 instead of only rescales ). The logarithm of the inverse ratio , taken so that it comes out positive, is then : linear in and in .
BEER-LAMBERT LAW
Holds for light of one wavelength, a dilute solution, no scattering and no reaction of the absorber. is absorbance (no unit), the molar absorptivity in L/(mol cm) at that wavelength, the concentration in mol/L, the path length in cm.
Measure at the wavelength of strongest absorption: absorbance plotted against wavelength is flat at its peak, so a small wavelength error changes least. Keep below about 1, since beyond it under 10% of the light passes and stray light (light of other wavelengths leaking to the detector) upsets the reading. comes from standard solutions: against is a straight calibration line of slope .
WATCH OUT FOR
Absorbance is a logarithm, not the fraction absorbed. Test: means , so 10% passes, not 100% absorbed.
Ultraviolet-visible spectra show electronic transitions. A longer conjugated chain has a smaller gap between its highest filled and lowest empty pi orbitals (Chapter 2), so it absorbs at a longer wavelength. In an octahedral complex of a transition metal, visible light can lift a d electron from to , so the absorption maximum gives the splitting .
WORKED EXAMPLE
A solution of a dye in a 1.00 cm cell has at its absorption maximum. For the dye, L/(mol cm) at that wavelength. Find the concentration.
Beer-Lambert holds here: one wavelength and a dilute dye, so use .
Put in the numbers: . Here has units L/mol, which leaves mol/L.
mol/L.
Answer: mol/L
A bond behaves like a spring joining two atoms. A stiffer bond and lighter atoms vibrate faster, and the molecule absorbs infrared light of that frequency. Stiffness and masses belong to the bond, so a group absorbs in nearly the same place in different molecules. Infrared positions are given as a wavenumber in cm, which is proportional to photon energy.
VIBRATIONAL WAVENUMBER OF A BOND
Harmonic-oscillator model, a good guide for small vibrations. is the bond's force constant in N/m; , are the atoms' masses and the reduced mass, in kg. is in s, so with cm/s, is in cm.
Group | Wavenumber (cm⁻¹) | Band |
|---|---|---|
O–H (alcohol) | 3200 to 3550 | Strong, broad |
N–H | 3300 to 3500 | Medium |
C–H (alkyl) | 2850 to 3000 | Medium to strong |
C≡N or C≡C | 2100 to 2260 | Weak to medium |
C=O | 1680 to 1750 | Very strong, sharp |
C=C | 1620 to 1680 | Weak to medium |
C–O | 1000 to 1300 | Strong |
A band is an absorption peak in the spectrum: strong or weak says how much light it absorbs, broad or sharp how wide it is. The table follows the formula. Between the same two atoms, a triple bond is stiffer than a double, and a double stiffer than a single. So C=O lies far above C–O, and C≡C above C=C. Bonds to hydrogen have the smallest , so O–H, N–H and C–H lie above every other band in the table; among those three is nearly equal and the order follows . A strong, sharp band near 1700 cm means a carbonyl group.
A nucleus spins, so it behaves like a small magnet. In a field it has two energy states, along the field or against it (a spin-1/2 nucleus). Radio waves whose equals the gap flip it, and the gap, so , is proportional to . Electrons around a nucleus shield it a little from , so hydrogens in different surroundings flip at slightly different frequencies.
CHEMICAL SHIFT
and are the resonance frequencies (Hz) of the hydrogen and of the reference, tetramethylsilane at , in the same . Both scale with , so dividing by the spectrometer frequency gives the same (ppm) at 400 and 600 MHz.
Hydrogen environment | δ (ppm) |
|---|---|
Alkyl C–H | 0.9 to 1.5 |
C–H next to C=O | 2.0 to 2.5 |
C–H on a carbon bonded to O | 3.3 to 4.0 |
Aromatic C–H | 6.5 to 8.0 |
Aldehyde C–H | 9 to 10 |
Equivalent hydrogens sit in identical surroundings, like the three of a group: they give one peak and do not split each other. A peak's area is proportional to its number of equivalent hydrogens. In simple spectra, a peak splits into lines when its hydrogens have equivalent neighbours on adjacent carbons. Each neighbour is itself a small magnet, along or against , and slightly shifts the field the hydrogens feel; neighbours give different totals (0, 1, ..., of them against), so lines. In the peak has 3 lines and the peak 4, areas 3 : 2.
Chromatography separates components that move at different speeds. A mobile phase (a liquid or gas) carries the mixture past a stationary phase (a solid, or a liquid held on a solid); a component held more strongly lags behind. In thin-layer chromatography the stationary phase is silica gel or alumina on a plate; in paper chromatography, water held in the paper's fibres. In both, the mixture is spotted on a starting line and a solvent rising past it is the mobile phase.
RETENTION FACTOR
Both distances run from the starting line: to the centre of the spot and to the solvent front. lies between 0 and 1, has no unit, and is smaller for a component held more strongly. It repeats only for one solvent, stationary phase and temperature, so identify a compound by running it beside a known sample.
Accuracy is how close a result is to the true value. Precision is how close repeated readings are to each other. A fixed error, such as a wrongly calibrated burette, shifts every reading alike: it spoils accuracy and leaves precision untouched. The spread of repeated readings, their standard deviation, measures precision.
STANDARD DEVIATION OF REPEATED READINGS
For randomly scattering readings, . are the readings, their mean, in the unit of . Readings lie closer to their own mean than to the true value, so squares about come out too small; dividing by makes up for it. One reading gives : it says nothing about spread.
UNCERTAINTY OF THE MEAN
For independent readings with random scatter. Random errors partly cancel in an average, so the mean scatters times less than one reading. , the standard error of the mean, is in the unit of . A fixed error does not shrink.
WORKED EXAMPLE
Four burette readings of a titre are 25.1, 25.3, 25.2 and 25.4 mL. Report the mean with its uncertainty.
The mean is mL.
The deviations from the mean are , , , mL. Their squares add to mL².
Divide by because came from these readings: . So mL.
Uncertainty of the mean: mL. An uncertainty is itself only roughly known, so quote it to one figure, 0.06 mL, and give the mean to the same decimal place.
Answer: mL
A solution in a 2.00 cm cell has . Its molar absorptivity is L/(mol cm). Find its concentration in units of mol/L.
Answer: (accepted range )
.
mol/L, so the answer is 1.0.
In thin-layer chromatography the solvent front travels 9.0 cm from the starting line and a spot travels 3.6 cm. Find .
Answer: (accepted range )
.
.
On a 600 MHz NMR spectrometer, a peak lies at ppm from the reference. How far from the reference is it in Hz?
210 Hz
2100 Hz
21000 Hz
0.0058 Hz
Answer: (B)
.