The whole Electrical and Electronic Measurements formula sheet, to print

167 formulas in 6 topics, each with when to use it. Each is explained in the topic notes.

Units, standards, errors and uncertainty

Read the notes

STATIC (ABSOLUTE) ERROR AND CORRECTION

Sign convention used throughout these notes: error = measured minus true, so a positive error means the instrument reads high. The correction is what must be added to the reading to get the true value. Some texts define the error with the opposite sign; check the convention a question uses.

RELATIVE (FRACTIONAL) ERROR

Taken relative to the true value unless the question says otherwise. When the error is small, dividing by instead changes the result only in the second order. An accuracy quoted as a percentage of full scale is a different quantity (see limiting errors).

RELATIVE ACCURACY

Accuracy is the complement of the relative error: a reading 2% in error is 98% accurate.

STATIC SENSITIVITY AND DEFLECTION FACTOR

Change in steady output per change in input ; for a linear instrument, the slope of its calibration line. The unit combines output and input units.

VOLTMETER LOADING ERROR

Voltmeter of resistance across a source of open-circuit (Thevenin) voltage and internal (Thevenin) resistance . The error is always negative (the meter reads low) and shrinks as grows. For a PMMC voltmeter, = (ohms-per-volt sensitivity) (range in use), where ohms-per-volt , the reciprocal of the full-scale current.

AMMETER INSERTION (LOADING) ERROR

Ammeter of resistance inserted in a branch; is the current before insertion and the Thevenin resistance of the circuit seen from the break. The ammeter always reads low; the error is small when .

LIMITING ERROR OF A COMPONENT OR READING

= nominal or specified value, = guaranteed bound, = actual value, which can lie anywhere in the band.

FULL-SCALE SPECIFICATION: LIMITING ERROR AT A READING

For an accuracy quoted as a fraction of the full-scale value . At half scale the relative limiting error is twice the quoted figure; at one-tenth scale, ten times. Hence the range is chosen so that the reading falls in the upper part of the scale. A specification as a percentage of span uses the span (upper minus lower range value) in place of ; the two differ only for a range that does not start at zero.

SUM OR DIFFERENCE

Absolute limiting errors add, for a difference as well as a sum. For a difference, is small when , so the relative error can be very large.

PRODUCT OR QUOTIENT

Relative limiting errors add, for a quotient as well as a product.

POWERS (GENERAL PRODUCT FORM)

Each relative error is weighted by the magnitude of its exponent, whether positive, negative or fractional ( is an exact constant). gives ; gives .

GENERAL FUNCTION (WORST CASE)

Linearised, so valid for small errors. Use it whenever a variable appears more than once, as in : applying the product and sum rules separately treats the two appearances as independent, which can only overstate the error, never understate it.

ARITHMETIC MEAN AND DEVIATION

The deviations from the mean always sum to zero, a useful arithmetic check.

AVERAGE DEVIATION

Magnitudes are needed because the signed deviations cancel. For a large normally distributed set, .

STANDARD DEVIATION AND VARIANCE

(divide by ) describes a whole population or a very large set. (divide by ) is the estimate from a finite sample, because one degree of freedom is used up in computing ; the difference matters only when is small. Use the one the question asks for.

PROBABLE ERROR

Half of a large set of normally distributed readings lie within . Use the same or that the question specifies.

STANDARD DEVIATION OF THE MEAN

Scatter of the mean of independent readings, each of standard deviation . Quadrupling the number of readings halves it; it does nothing to systematic error.

TYPE A STANDARD UNCERTAINTY (MEAN OF REPEATED READINGS)

is the sample standard deviation (with ) of the readings.

TYPE B STANDARD UNCERTAINTY

are the limits. Rectangular when any value within the limits is equally likely (a tolerance with no further information); a display of resolution gives , so . A certificate quoting at coverage factor gives .

COMBINED STANDARD UNCERTAINTY

For with uncorrelated inputs. is the sensitivity coefficient of input . The same root-sum-square rule propagates the standard deviations, or the probable errors, of independent quantities: and .

RELATIVE COMBINED UNCERTAINTY FOR A PRODUCT FORM

The statistical counterpart of the power rule for limiting errors: relative uncertainties weighted by the exponents, squared, added, square-rooted.

EXPANDED UNCERTAINTY AND THE REPORTED RESULT

gives about 95% coverage and about 99.7% when the combined distribution is close to normal with many degrees of freedom. State with the result.

JOSEPHSON VOLTAGE STANDARD

A junction irradiated at microwave frequency shows constant-voltage steps at integer , each high: about V per GHz. Since 2019 is exact. junctions in series, each on step , give ; arrays of thousands of junctions give 1 V and 10 V.

QUANTUM HALL RESISTANCE STANDARD

In a two-dimensional electron gas at low temperature and high magnetic field, the Hall resistance takes plateau values for integer , independent of the sample's dimensions and material. The plateau, , is commonly used.

LEAST-SQUARES STRAIGHT LINE (UNWEIGHTED)

Every point equally reliable. The line passes through the centroid and the residuals sum to zero.

SLOPE IN DEVIATION FORM

Same slope as above with smaller numbers. and .

LINE THROUGH THE ORIGIN

Only when the model is known to have zero intercept. This line does not in general pass through the centroid.

WEIGHTED LEAST-SQUARES STRAIGHT LINE

The line passes through the weighted centroid .

WEIGHTED MEAN

Combines independent measurements of the same quantity made with different precision. The combined uncertainty is smaller than the smallest individual one; with equal it reduces to and .

Bridges, potentiometers and the Q-meter

Read the notes

WHEATSTONE BRIDGE BALANCE

Products of opposite arms are equal. The condition does not involve , or the source resistance, and it is unchanged if the supply and the galvanometer are interchanged (only the sensitivity changes).

LIMITING ERROR OF A WHEATSTONE MEASUREMENT

Limiting error is a guaranteed (worst-case) bound: for a product or quotient, the relative limiting errors of the factors add, whether a factor multiplies or divides. For example, arms each known to give to within . Any lack of detector sensitivity (the smallest unbalance that can be seen) adds to this.

UNBALANCED BRIDGE: THEVENIN EQUIVALENT AT THE GALVANOMETER TERMINALS

Open-circuit voltage of B with respect to D, and the resistance seen from B–D. This simple holds for a supply of negligible internal resistance; with a source resistance, find by a delta–star conversion instead.

GALVANOMETER CURRENT AND DEFLECTION

Current in a galvanometer of resistance connected across an unbalanced bridge. is the galvanometer's current sensitivity (e.g. mm/μA).

SMALL UNBALANCE, AND THE EQUAL-ARM BRIDGE

Change in the open-circuit output when the unknown moves from its balance value to , with for the approximate forms. For a given , is largest at , so equal arms give the largest open-circuit output per ohm of unbalance. The middle form is exact and shows the output is linear only for small .

QUARTER, HALF AND FULL BRIDGES (EQUAL ARMS $R$, SUPPLY $E$)

Open-circuit output with one, two or four active arms (e.g. strain gauges), each changing by . The active arms must be placed so their effects add: two adjacent arms must change in opposite senses, two opposite arms in the same sense. The full bridge, and the half bridge with two adjacent arms changing in opposite senses, are exactly linear. The quarter bridge, and a half bridge with two opposite arms changing in the same sense (exact output ), are linear only for small .

KELVIN DOUBLE BRIDGE BALANCE

= outer ratio arms; = inner ratio arms ( and on the side of the unknown , and on the side of the standard ); = resistance of the link between and . The second term is the error caused by the link, and it has the sign of .

KELVIN DOUBLE BRIDGE WITH MATCHED RATIOS

In practice the two ratio pairs are ganged so they stay equal, the link is made short and thick so any residual mismatch multiplies a small , and every ratio arm is made much larger than the lead and contact resistances in series with it. Used for resistances below about 1 Ω, such as shunts and busbar sections.

LOSS-OF-CHARGE METHOD

A capacitor charged to discharges through the unknown ; is the voltage after time , read on a voltmeter that draws no current (an electrostatic voltmeter). It suits very high resistances, where the decay is slow enough to time accurately; with a small the voltage collapses too quickly.

LOSS OF CHARGE: CORRECTING FOR THE CAPACITOR'S OWN LEAKAGE

is the leakage resistance of the capacitor itself (together with that of the voltmeter), found by a second test with disconnected. It is always in parallel with , so the first test gives .

GENERAL AC BRIDGE BALANCE

Products of the impedances of opposite arms are equal. The admittance form is convenient when arms are parallel combinations.

MAGNITUDE AND PHASE CONDITIONS

Both must hold at once. is the impedance angle: positive for an inductive arm, negative for a capacitive arm, zero for a pure resistance.

Q OF A COIL AND DISSIPATION FACTOR OF A CAPACITOR

Subscript = series equivalent circuit, = parallel equivalent circuit; in the parallel model the coil's . is the loss angle: minus the angle by which the capacitor's current leads its voltage. For small the capacitor's power factor . For a coil, . From here on denotes a quality factor, not a ratio arm of the DC bridges.

SERIES–PARALLEL EQUIVALENTS AT ONE FREQUENCY

Converts between the series model (natural for an arm like ) and the parallel model. For , and agree within 1%; for small , .

MAXWELL INDUCTANCE (COMPARISON) BRIDGE

Arm 2 is a variable standard inductor with total series resistance (its own resistance plus any added resistor); arms 3 and 4 are resistors, opposite the unknown and opposite the standard. From . Frequency-independent; its drawback is the need for a variable standard inductor.

MAXWELL–WIEN (MAXWELL INDUCTANCE–CAPACITANCE) BRIDGE

Arm 4 = in parallel with a standard capacitor . From . The balance equations are free of frequency, and if and are the adjusted elements the two conditions are independent. Suited to medium-Q coils (roughly ).

HAY'S BRIDGE

Arm 4 = in series with . From . Both and depend on , so the frequency must be known. Suited to high-Q coils ().

HAY'S BRIDGE IN TERMS OF Q

Because . The approximation overstates by the factor : 1% at , 0.25% at . Use the exact form when a question gives and all the element values.

ANDERSON BRIDGE

Topology as described above: the series – branch is in parallel with , and the detector taps its midpoint. is the total resistance of the coil's arm: if a variable resistor is added in series with a coil of resistance to obtain balance, . The balance is frequency-independent, and does not appear in the resistance condition.

SCHERING BRIDGE BALANCE

From . Both equations are free of frequency. , the resistor in the arm opposite the unknown, is in the numerator for .

SCHERING BRIDGE DISSIPATION FACTOR

Series-model dissipation factor of the unknown; unlike and , it contains . With fixed, the dial can be calibrated directly in at one frequency, and is varied for the balance.

WIEN BRIDGE BALANCE FREQUENCY

From the imaginary part of : .

WIEN BRIDGE RESISTANCE-RATIO CONDITION

Real part of the same equation. is the resistor opposite the parallel-RC arm, the one opposite the series-RC arm.

EQUAL-ELEMENT WIEN BRIDGE

With ganged and equal fixed capacitors, one dial reads frequency directly. At the series-RC/parallel-RC divider passes exactly one third of the voltage with zero phase shift, which is why a Wien-bridge oscillator's amplifier needs a gain of 3.

Q-METER PRINCIPLE

At resonance the loop's reactances cancel, so the current is ( = coil resistance) and the capacitor voltage is times the injected voltage. Assumes and the capacitor's losses are negligible compared with , the voltmeter does not load the circuit, and the self-capacitance is neglected.

INDUCTANCE FROM THE RESONANCE SETTING

= the coil's self (distributed) capacitance, which adds to the tuning capacitance as far as the resonant frequency is concerned. Neglect it only when .

CORRECTION FOR THE SHUNT (INSERTION) RESISTANCE

The shunt is part of the resonant loop, so the measured is slightly low. The correction is negligible when and matters for coils of very low resistance.

SELF-CAPACITANCE BY THE TWO-FREQUENCY METHOD

and are the tuning-capacitor settings for resonance at and at the higher frequency . From at both frequencies: .

CORRECTION FOR SELF-CAPACITANCE

is the reading taken at tuning setting . The self-capacitance acts across the coil's terminals, so the indicated Q falls short of the coil's true by the factor .

SLIDE-WIRE COMPARISON

and are the balance lengths for the standard emf and the unknown at the same working current , on a uniform wire of resistance per unit length; is the potential gradient (volts per unit length).

EXTENDING THE RANGE: VOLT-RATIO BOX

A precision resistive divider presents to the potentiometer ( = ratio, e.g. 10 or 100) and is the potentiometer reading. Unlike the potentiometer itself, the divider draws current from the circuit under test.

CURRENT MEASUREMENT

The potentiometer reads the drop across a four-terminal standard resistor carrying the current. This is how ammeters are calibrated.

RESISTANCE BY COMPARISON

and a standard carry the same current in series, and the potentiometer reads the two drops in quick succession. Suitable for low resistances, because only the potential terminals are involved.

COORDINATE-TYPE AC POTENTIOMETER

= in-phase component, = quadrature component, both measured against the potentiometer's reference phase; the signs of and fix the quadrant of . The polar type gives and directly.

Measuring voltage, current, power, energy and power factor

Read the notes

PMMC DEFLECTION

is the number of turns, the gap flux density, the coil area and . With a varying current the inertia of the moving system averages the torque, so follows the average (DC) value. The scale is linear, and the pointer tries to deflect backwards if the current reverses.

MOVING-IRON DEFLECTION

Derived from stored energy. Torque is proportional to , so the direction of deflection does not depend on polarity and is the rms value on AC. The scale is square-law unless the vane is shaped so that falls as increases.

ELECTRODYNAMOMETER DEFLECTING TORQUE (AVERAGE)

and are the rms currents in the fixed and moving coils, and is the angle between them (on DC, use the DC currents with ). Used as an ammeter or voltmeter, it reads rms and has the same calibration on DC and AC.

RMS AND AVERAGE VALUES

is one full period. A PMMC reads the signed mean , which is zero for a symmetric AC wave. Do not confuse it with .

FORM FACTOR AND CREST (PEAK) FACTOR

For a sine wave, and .

RMS OF A WAVE WITH DC AND HARMONICS

is the DC component, and are the rms values of components at different frequencies, whose cross-products average to zero. For two sinusoids of the same frequency, add them as phasors first.

FULL-WAVE RECTIFIER METER READING

Applies to an average-responding full-wave meter whose scale is marked in rms of a sine. is the mean of . The reading is correct only when the wave's .

HALF-WAVE RECTIFIER METER READING

Applies to an average-responding half-wave meter with its scale marked in rms of a sine. Only the conducting half-cycle contributes. Reversing the leads measures the other half, which gives a different reading on an asymmetric wave.

FORM-FACTOR ERROR OF AN AVERAGE-RESPONDING METER

Applies to a full-wave average-responding meter calibrated for a sine, with computed from the mean of . The error is a percentage of the TRUE rms of the applied wave. Square wave (): . Triangle (): .

AMMETER SHUNT

is the multiplying power: the new full-scale current divided by the movement's full-scale current. The shunt and the movement share the same voltage.

VOLTMETER MULTIPLIER

is the desired full-scale voltage. The total meter resistance is .

VOLTMETER SENSITIVITY AND RESISTANCE

The voltmeter's resistance depends on the RANGE selected, not on the reading. A higher sensitivity (smaller ) means less loading.

AC SENSITIVITY OF A RECTIFIER VOLTMETER

For a PMMC movement with ideal diodes and a scale marked in rms of a sine, where . A sine of rms value has a mean of after full-wave rectification and after half-wave rectification, so the total resistance for full scale on an AC range is or .

VOLTMETER LOADING

and form the Thevenin equivalent seen from the voltmeter's terminals, and is the true (unloaded) voltage. The error is a percentage of the true value and is always negative.

AMMETER INSERTION ERROR

is the Thevenin resistance of the loop the ammeter is inserted into, and is the ammeter's resistance. The error is a percentage of the true current, and the current is always reduced.

COMPENSATED VOLTAGE PROBE (RC DIVIDER)

includes the capacitance of the scope input and the cable. Example: a 9 MΩ tip resistor with a 1 MΩ ∥ 18 pF input gives 10:1 and needs pF. The circuit under test then sees 10 MΩ in parallel with 1.8 pF. When the condition holds, the division ratio is the same at all frequencies.

SCALING THROUGH INSTRUMENT TRANSFORMERS

is the nominal ratio, primary:secondary. For example, a 100/5 A CT has , and an 11 kV/110 V PT has . Ratio and phase-angle errors are neglected here.

DC POWER, VOLTMETER ACROSS THE LOAD

The ammeter carries the load current plus the voltmeter's current. This connection is preferred for low-voltage, high-current loads.

DC POWER, AMMETER NEXT TO THE LOAD

The voltmeter reads the load voltage plus the ammeter's drop. This connection is preferred for high-voltage, low-current loads.

SINGLE-PHASE POWER

and are rms values of sinusoids. is the angle by which the current lags the voltage: for a lagging (inductive) load, and .

THREE-VOLTMETER METHOD

A known non-inductive resistance is connected in series with the load. is the voltage across the series combination, the voltage across and the voltage across the load; and are the load's. It follows from the phasor sum with .

THREE-AMMETER METHOD

A known non-inductive resistance is connected in parallel with the load. is the total current, the current in and the load current. It follows from with .

ACTIVE POWER WITH NON-SINUSOIDAL VOLTAGE AND CURRENT

and are the DC components, and the rms values of the th harmonics, and the angle between them. Products of components at different frequencies average to zero, so a harmonic present in only one of and contributes no power. An electrodynamometer wattmeter with negligible PC inductance reads this . and are the full rms values, including every harmonic.

READING WITH PRESSURE-COIL INDUCTANCE

Applies to a wattmeter calibrated on DC with a PC resistance of , on a sinusoidal supply. The PC current lags by . is positive for a lagging load and negative for a leading load.

CORRECTION FACTOR FOR PRESSURE-COIL INDUCTANCE

Multiply the reading by this factor. Equivalently, .

APPROXIMATE ERROR DUE TO PRESSURE-COIL INDUCTANCE

Valid for small . A lagging load makes the wattmeter read high, and a leading load makes it read low. The error grows quickly as the power factor falls.

CONNECTION (COIL-LOSS) ERROR

is the CC resistance and the PC-circuit resistance. With the PC on the load side, the CC carries the PC current as well as the load current. Choose the connection whose extra loss is smaller: the load-side PC for high-current, low-voltage loads, and the supply-side PC for low-current, high-voltage loads.

WATTMETER FULL-SCALE VALUE AND MULTIPLYING FACTOR

and are the rated (range) voltage and current, and is the rated power factor: 1 for a standard wattmeter, and the stated low value (for example 0.2) for a low power-factor wattmeter. The multiplying factor is in watts per division. When the wattmeter is fed through a CT and a PT, multiply further by .

TWO-WATTMETER READINGS, BALANCED LOAD

For a balanced sinusoidal load, with the load phase angle (positive for lagging). With phase sequence RYB, current coils in lines R and Y and both pressure coils returned to B, is the wattmeter in line R.

POWER, REACTIVE POWER AND POWER FACTOR FROM TWO WATTMETERS

holds for ANY 3-wire load. and hold only for a balanced sinusoidal load. A negative reading enters every formula with its sign.

POWER FACTOR FROM THE RATIO OF THE READINGS

For a balanced sinusoidal load, with the larger reading and entered with its sign, so . It follows from the expression. Checks: gives 1, gives 0.5, and gives 0.

REACTIVE POWER WITH ONE WATTMETER

For a balanced sinusoidal 3-wire load, with the current coil in one line and the pressure coil across the other two lines (for sequence RYB: CC in R, PC from Y to B). Reversing the pressure-coil connection or the phase sequence reverses the sign of the reading.

THREE-PHASE POWER, OTHER METHODS

The one-wattmeter method needs the neutral, or an artificial star point, for its pressure coil. The last expression is for a balanced sinusoidal load. and are line values, and is the phase angle of each phase's load impedance.

METER CONSTANT AND DISC SPEED

is in rev/kWh (imp/kWh for an electronic meter), in kWh and in kW. Check the units given: some meters state the constant in kWh per revolution or W·s per revolution instead.

ENERGY-METER ERROR

The error is a percentage of the true energy. A positive error means the meter registers more than was consumed (it runs fast).

POWER FROM AN ELECTRONIC METER'S PULSES

is the number of pulses counted in seconds, and is in imp/kWh.

POWER-FACTOR METER AND INDIRECT POWER FACTOR

The indirect forms use wattmeter, voltmeter and ammeter readings. For a balanced three-phase load, the two-wattmeter method gives directly.

Instrument transformers

Read the notes

NOMINAL RATIO

Read off the rating plate and fixed for the transformer. For example, 1000/5 A gives and 11000/110 V gives . Readings are normally multiplied by .

ACTUAL RATIO (TRANSFORMATION RATIO)

The ratio of the actual primary magnitude to the actual secondary magnitude at the operating point. It is not constant: it changes with the primary current or voltage, the burden and the burden power factor.

TURNS RATIO

Both are defined so that . A bar (single-turn) primary CT has , so . With turns compensation, is made slightly smaller than .

RATIO CORRECTION FACTOR

An RCF above 1 means the nominal-ratio figure is too low. For an ideal transformer RCF = 1. In terms of RCF, ratio error .

RATIO ERROR (CURRENT ERROR OR VOLTAGE ERROR)

The error in the value obtained with the nominal ratio, as a percentage of the true value. Positive means reading is high and negative means it is low. For a PT, replace with . If the ratio error is (as a fraction), then .

CT SECONDARY EMF AND CORE FLUX

is the impedance magnitude of the whole secondary circuit (winding, leads and burden); is the peak core flux, the peak flux density and the core cross-section, for sinusoidal flux at frequency . The flux the CT must carry, and so its exciting current, is set by and the burden impedance, which is why the core flux follows the line current.

CT ACTUAL RATIO

Valid when . Since , : the correction term is always positive, so . An uncompensated CT () therefore has and a negative ratio error, approximately , which means it reads low.

CT PHASE ANGLE

Positive (the reversed secondary current leads ) while , zero at and negative beyond. Here is the secondary current referred to the primary.

CT WITH A PURELY RESISTIVE SECONDARY CIRCUIT

Use this when the secondary circuit, winding included, is purely resistive. The loss component then sets the ratio error and the magnetising component sets the phase angle.

BURDEN IN OHMS

The burden includes the leads. On a CT the instruments are in series, so their impedances add. On a PT they are in parallel, so their admittances add. Examples: 15 VA on a 5 A CT is 0.6 Ω, 15 VA on a 1 A CT is 15 Ω, and 100 VA on a 110 V PT is 121 Ω.

PT ACTUAL RATIO

Valid when the winding drops are small compared with (the normal case), so the exciting-current components can be taken in phase with and in quadrature to the reversed secondary voltage. At no load () this becomes . The load term is proportional to , so for a burden of fixed power factor the ratio, and hence the ratio error, changes almost linearly with the burden VA.

PT PHASE ANGLE

Sign as on this page: positive when the reversed secondary voltage leads . At no load it is . The load term is negative whenever , and in that case adding burden swings the reversed secondary voltage towards lagging . Setting gives the burden at which the phase angle vanishes; for a unity-power-factor burden () that is .

ANGLE SEEN BY THE WATTMETER

is positive for a lagging load. and are positive when the reversed secondary phasor leads its primary. A leading CT phase angle makes a lagging load look closer to unity power factor.

TRUE POWER FROM THE WATTMETER READING

and are the actual PT and CT ratios at the operating point. The same factors multiply the energy registered by an energy meter. If ratio errors are neglected, replace with .

ERROR OF THE NOMINAL-RATIO POWER (SMALL ERRORS)

. Here and are the PT and CT ratio errors in percent, and the phase angles are in radians. Valid while the ratio errors are small and ; for a leading load , and so , is negative. Because of the factor, phase-angle errors are negligible near unity power factor and large at low power factor.

Digital voltmeters, multimeters and energy meters

Read the notes

RESOLUTION OF AN N½-DIGIT DISPLAY

N is the number of full digits, so for 3½ digits N = 3 and R = 0.001. R is the smallest step as a fraction of the decade range. The half digit adds overrange, not resolution.

COUNTS OF AN N½-DIGIT DISPLAY

3½ digit: 2000 counts, maximum display 1999. 4½ digit: 20000 counts, maximum 19999. A plain N-digit display has counts.

VALUE OF ONE COUNT (ONE 'DIGIT') ON A RANGE

This is the place value of the last displayed digit. Use the first form when ranges are named by decade (1 V, 10 V, ...). Use the second when they are named by full count (2 V, 20 V, ... on a 2000-count meter).

SENSITIVITY OF A DVM

is the full scale of the lowest range, taken at its decade value. For example, a range that reads up to 199.9 mV counts as 100 mV. S is the smallest change in input the meter can display at all, and it equals the place value of the last digit on the lowest range.

LIMITING ERROR FOR ±(A% OF READING + M COUNTS)

is the value of one count on the range in use. The two terms are added because this is a worst-case bound.

LIMITING ERROR AS A PERCENTAGE OF READING

The count term is fixed in volts, so the percentage error rises as the reading falls.

SINGLE-SLOPE RAMP DVM

is the ramp slope in V/s and is the clock frequency. Both must be accurate and stable, because nothing cancels them and nothing averages out noise.

DUAL-SLOPE BALANCE

Use magnitudes; and have opposite polarity. For an input that varies during run-up, here is its average over . R, C and cancel as long as they stay constant for one conversion, so the only component value the reading depends on is . The integrator, switches and comparator must still behave ideally (linear and free of offset), and the result is quantised to ±1 count.

PEAK INTEGRATOR OUTPUT

Assumes a dc input and an integrator that starts from 0 V. At full-scale input this must stay inside the op-amp's output swing, which sets the smallest usable RC.

DUAL-SLOPE CONVERSION TIME

For a dc input. Add any auto-zero time on top. Integrating DVMs are slow compared with successive-approximation and flash converters, because is usually one or more periods of the power-line frequency.

NORMAL-MODE REJECTION OF AN INTEGRATING DVM

Assumes a sinusoidal interference of frequency f added to the input, and a reading equal to the average of the input over . NMRR is the ratio of the peak interference to the worst-case error it causes in that average. It is infinite (ideal rejection) when is a whole number, that is, when is an integer multiple of the interference period.

ADC RESOLUTION (SIZE OF 1 LSB)

is the full-scale input range. Some treatments use because they define the top code as equal to ; use whichever definition the question gives. An ideal rounding converter has quantisation error ±½ LSB.

SAR CONVERSION TIME

This is fixed and does not depend on . Some designs add start or end-of-conversion clock cycles on top.

STAIRCASE (COUNTER) RAMP: WORST-CASE CONVERSION TIME

The conversion time varies with . A full-scale input takes the longest.

FLASH ADC HARDWARE

All comparisons happen in parallel, so a conversion takes one clock period. An 8-bit flash converter needs 255 comparators.

LOADING ERROR ON THE DC VOLTAGE FUNCTION

The source is modelled as its Thevenin equivalent (, ), and is the DMM's input resistance. The error is taken relative to the true (unloaded) voltage . It is negative: the meter always reads low.

AVERAGE-RESPONDING METER, CALIBRATED IN RMS OF A SINE WAVE

is the full-wave rectified average of the actual waveform. The indication equals the true rms only for a sinusoid, because 1.11 is the sine form factor. A half-wave average-responding meter instead multiplies the half-wave average by ; it too is correct only for a sine.

WAVEFORM ERROR OF AN AVERAGE-RESPONDING METER

is the true rms of the actual waveform, so this error is relative to the true value. is 1.11 for a sine, 1 for a square wave and for a triangle wave. So a square wave reads 11.1% high and a triangle wave reads about 3.8% low.

TOTAL RMS OF A WAVEFORM WITH A DC COMPONENT

An ac-coupled true-rms meter shows only . To get the total rms, combine it with the dc reading as shown.

ACTIVE POWER FROM SAMPLES

The samples must span a whole number of cycles; otherwise the reading ripples. It stays correct when harmonics are present, provided the sampling rate satisfies .

ENERGY ACCUMULATION

is the sampling interval. Energy is the running sum of instantaneous power × time.

METER CONSTANT: PULSES AND ENERGY PER PULSE

C is the meter constant in impulses per kWh (imp/kWh). For example, C = 3200 imp/kWh gives 0.3125 Wh (1125 J) per pulse.

PULSE RATE AT CONSTANT POWER

P is the active power in kW and C is in imp/kWh.

PERCENTAGE ERROR OF AN ENERGY METER

Error is taken relative to the true energy. It is positive when the meter over-registers. in kWh.

Time, phase and frequency measurement, oscilloscopes and spectrum analysers

Read the notes

FREQUENCY MODE

= input cycles counted in the gate time . A 1 s gate reads to 1 Hz and a 10 s gate to 0.1 Hz.

PERIOD MODE (MULTIPLE-PERIOD AVERAGE)

= clock (time-base) frequency and = number of input periods the gate stays open for ( for a single period). Averaging makes the resolution .

GATING ERROR (ANY MODE)

As a fraction of the reading. The error is ±1 count whatever the input.

GATING ERROR IN FREQUENCY MODE

Large at low frequencies. A 50 Hz input with a 1 s gate gives , which is an error of ±2%.

GATING ERROR IN PERIOD MODE

Small at low frequencies. It grows with the input frequency.

TOTAL LIMITING ERROR

The worst-case (guaranteed) bound as a fraction of the reading. In period and time-interval modes, add the trigger error.

CROSSOVER (MODE-CHANGEOVER) FREQUENCY

The frequency at which the ±1-count error is the same in both modes, found by setting . Below , measure the period and invert it. Above it, measure frequency directly.

ELECTROSTATIC DEFLECTION ON THE SCREEN

is measured from the centre of the plates to the screen. Assumes a uniform field between the plates (no fringing), a small deflection angle and a beam that clears the plates. cancels, so the deflection does not depend on it.

DEFLECTION SENSITIVITY AND DEFLECTION FACTOR

Convention used here: sensitivity is deflection per volt, and the deflection factor is volts per unit deflection (the V/div knob sets a deflection factor). Doubling halves the sensitivity.

READING THE GRATICULE

and are numbers of divisions. = probe attenuation (10 for a 10:1 probe, unless the scope already corrects for it). For a sine, .

PHASE FROM TIME DELAY

is the delay between corresponding points and the common period. On a CRO, = (divisions of delay)/(divisions per cycle), so the time/div setting cancels.

FLIP-FLOP (SET–RESET) PHASE DETECTOR

The output switches between 0 and . The positive-going zero crossing of the reference sets the flip-flop and the positive-going zero crossing of the other signal resets it, so the duty cycle is , where is the lag of the other signal behind the reference. The reading is unambiguous over the full circle: a 30° lag reads 30° and a 30° lead reads 330°.

XOR PHASE DETECTOR

The output switches between 0 and . Both inputs must be square waves of 50% duty cycle (sinusoids are squared first by comparators). The output is high whenever the inputs differ, which happens twice per cycle. For the output is , so the detector cannot tell a lag of from a lead of .

LISSAJOUS FREQUENCY RATIO

is on the Y (vertical) input and on the X (horizontal) input. = points touching a horizontal tangent; = points touching a vertical tangent. For an open figure whose ends are retraced, each free end counts as ½.

LISSAJOUS PHASE (SAME FREQUENCY)

= the distance from the centre to the point where the ellipse cuts the Y axis (half the chord on the Y axis); = the maximum vertical deflection. The ratio of full chord to full height is the same. Centre the figure first, and assume the X and Y amplifiers add equal phase shifts. This gives the size of φ only, not whether Y leads or lags, and alone cannot separate φ from : the quadrants of the major axis decide.

PROBE COMPENSATION CONDITION

and = the probe's series resistance and its trimmer capacitor; and = the scope's input resistance and total shunt capacitance (input plus cable). When compensated, the attenuation holds at every frequency.

COMPENSATED K:1 PROBE AS SEEN BY THE CIRCUIT

Loading falls by the attenuation factor. For a 10:1 probe, the circuit sees ten times the resistance and one tenth of the capacitance of the bare scope input. With a source resistance , forms a low-pass filter that adds a rise time of about .

RISE TIME AND BANDWIDTH

10%–90% rise time of a single-pole (first-order) response, from and . Use 0.35 unless the question gives another constant.

CASCADED RISE TIMES

Root-sum-square rule for cascaded stages with little or no overshoot. It is an approximation (exact for Gaussian responses). To find the true rise time of the signal, subtract the squares.

SAMPLING THEOREM

For a signal with no components above . The inequality is strict: at exactly , every sample can fall on a zero crossing. In practice a real-time DSO samples well above so that the reconstructed trace is accurate; a common rule of thumb is at least 2.5 samples per cycle of the highest frequency with interpolation and about 10 with linear interpolation.

ALIAS FREQUENCY

Any input above that is still inside the analogue bandwidth (with no anti-aliasing filter) is displayed at . For example, a 1.02 MHz sine sampled at 1 MS/s appears as a 20 kHz sine.

RECORD LENGTH, TIME WINDOW AND SAMPLE RATE

For a 10-division screen filled by the record. With a fixed memory, a slower time base forces a lower sample rate, which is how aliasing appears at slow sweeps.

VERTICAL RESOLUTION

For an -bit ADC, taking one step as (some texts divide by ; the difference is negligible for large ). An 8-bit ADC gives 256 levels, so one step on a 10 V full-scale range is 39 mV.

FFT FREQUENCY RESOLUTION

The bin spacing of an -point FFT, which covers 0 to .

SUPERHETERODYNE TUNING

For an LO above the input (high-side LO). The image frequency also mixes down to ; an input filter or a high first IF keeps it out.

RESOLUTION BANDWIDTH AND NOISE FLOOR

Change in the displayed noise level when the RBW is changed from to (negative means lower). Displayed noise power is proportional to the RBW, so a 10× narrower RBW lowers the noise floor by 10 dB, while a sinusoid's displayed level stays the same, so small tones emerge from the noise. Two equal tones closer together than about one RBW merge into a single peak.

POWER IN DBM

Levels are shown relative to 1 mW. Convert to voltage with the system impedance, usually 50 Ω.

HARMONIC DISTORTION FROM A SPECTRUM

= rms value of the nth harmonic; = its level in dB read off the display. This THD is relative to the fundamental unless it is stated as a percentage of the total rms.